{"id":6549,"date":"2019-01-15T20:13:31","date_gmt":"2019-01-15T19:13:31","guid":{"rendered":"https:\/\/blogs.plombiers-reunis.com\/?p=6549"},"modified":"2019-01-15T20:13:31","modified_gmt":"2019-01-15T19:13:31","slug":"pompes-a-chaleur-et-climatiseurs-attention-aux-liaison-cuivre","status":"publish","type":"post","link":"https:\/\/plombiers-reunis.com\/v3\/energies-renouvelables\/pompes-a-chaleur-et-climatiseurs-attention-aux-liaison-cuivre.html","title":{"rendered":"Pompes a chaleur et climatiseurs, attention aux liaison cuivre"},"content":{"rendered":"\n<p>J\u2019attire l\u2019attention des lecteurs sur l\u2019utilisation des outils ad\u00e9quats a chaque op\u00e9ration. Si on n\u2019a pas les bons outils, on ne peut pas faire des belles r\u00e9alisations, c\u2019est la diff\u00e9rence justifi\u00e9 entre les pros et le bricoleurs \u00ab\u00a0<em>dont je me reconnais<\/em>\u00a0\u00bb&nbsp;.<\/p>\n\n\n\n<p>Il m\u2019arrive parfois de mettre en service des pompes a chaleur, (<em>oui j\u2019ai l\u2019habilitation<\/em>) et sur certaines mises en route je me trouve confront\u00e9 aux probl\u00e8mes de fuites sur les dudgeons des liaisons cuivre.<\/p>\n\n\n\n<!--more-->\n\n\n\n<p>J\u2019ai eu l\u2019occasion de v\u00e9rifier que certains installateurs ne sont m\u00eame pas \u00e9quip\u00e9s de dudgeonni\u00e8re&nbsp; et cr\u00e9ent ces raccordements a l\u2019aide d \u2018une matrice de plombier, ce qui cause non seulement la fragilisation du cuivre a cet endroit mais aussi des fuites quasi-impossibles a r\u00e9parer lors de la mise en pression.<\/p>\n\n\n\n<p>Un dudgeon sur les liaison frigorifiques, doit \u00eatre tr\u00e8s pr\u00e9cis, il s\u2019agit d\u2019un collet avec un angle a 45\u00b0, il rassemble a un collet battu sur les tuyaux de plomberie, mais avec une pr\u00e9cision extreme il doit \u00eatre r\u00e9alis\u00e9 avec un outil de pr\u00e9cision, aucun coup de marteau ne peut \u00eatre tap\u00e9 sur ce collet.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/climatisation\/pompes-a-chaleur-et-climatiseurs-attention-aux-liaison-cuivre.html\/attachment\/bty-19\" rel=\"attachment wp-att-6551\"><img decoding=\"async\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2019\/01\/dudgeonni%C3%A8re-1024x662.jpg\" alt=\"Dudgeonni\u00e8re\" class=\"wp-image-6551\"\/><\/a><\/figure><\/div>\n\n\n\n<p>Vue de plus pr\u00e8s, on constate la pr\u00e9cision du collet, le cuivre est super lisse sur la partie en contact avec le raccord conique m\u00e2le.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/climatisation\/pompes-a-chaleur-et-climatiseurs-attention-aux-liaison-cuivre.html\/attachment\/bty-18\" rel=\"attachment wp-att-6550\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"640\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2019\/01\/Dougeon-1024x640.jpg\" alt=\"dudgeon\" class=\"wp-image-6550\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2019\/01\/Dougeon-1024x640.jpg 1024w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2019\/01\/Dougeon-300x188.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2019\/01\/Dougeon-768x480.jpg 768w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2019\/01\/Dougeon.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>Dans cet exemple le raccordement est facilement accessible, mais dans certains cas, la liaison se trouve dans des endroits difficilement accessibles ce qui complique le serrage, il est donc indispensable que les raccordements soient de bonne qualit\u00e9.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/energies-renouvelables\/climatisation\/pompes-a-chaleur-et-climatiseurs-attention-aux-liaison-cuivre.html\/attachment\/bty-20\" rel=\"attachment wp-att-6552\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"503\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2019\/01\/Raccordement-1024x503.jpg\" alt=\"Raccordement\" class=\"wp-image-6552\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2019\/01\/Raccordement-1024x503.jpg 1024w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2019\/01\/Raccordement-300x148.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2019\/01\/Raccordement-768x378.jpg 768w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2019\/01\/Raccordement.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>Raccordement sur unit\u00e9 ext\u00e9rieure<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/energies-renouvelables\/climatisation\/pompes-a-chaleur-et-climatiseurs-attention-aux-liaison-cuivre.html\/attachment\/bty-21\" rel=\"attachment wp-att-6553\"><img decoding=\"async\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2019\/01\/Raccordemet-difficile-dacc%C3%A8s-1024x768.jpg\" alt=\"Raccord difficile d\u2019acc\u00e8s\" class=\"wp-image-6553\"\/><\/a><figcaption>Raccordement difficilement accessible sur l&rsquo;unit\u00e9 int\u00e9rieure<\/figcaption><\/figure>\n\n\n\n<p>Je demande aux poseur des pompes, de ne pas faire ces dudgeons ou alors, bien vouloir investir dans une dudgeonni\u00e8re de qualit\u00e9 ce qui facilitera grandement la mise en service.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>J\u2019attire l\u2019attention des lecteurs sur l\u2019utilisation des outils ad\u00e9quats a chaque op\u00e9ration. Si on n\u2019a pas les bons outils, on ne peut pas faire des belles r\u00e9alisations, c\u2019est la diff\u00e9rence justifi\u00e9 entre les pros et le bricoleurs \u00ab\u00a0dont je me reconnais\u00a0\u00bb&nbsp;. Il m\u2019arrive parfois de mettre en service des pompes a chaleur, (oui j\u2019ai l\u2019habilitation) &#8230; <a title=\"Pompes a chaleur et climatiseurs, attention aux liaison cuivre\" class=\"read-more\" href=\"https:\/\/plombiers-reunis.com\/v3\/energies-renouvelables\/pompes-a-chaleur-et-climatiseurs-attention-aux-liaison-cuivre.html\" aria-label=\"En savoir plus sur Pompes a chaleur et climatiseurs, attention aux liaison cuivre\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":6550,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"categories":[13],"tags":[440,728,937],"class_list":["post-6549","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-energies-renouvelables","tag-dudgeon","tag-liaison-cuivre","tag-pompe-a-chaleur"],"_links":{"self":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/6549","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/comments?post=6549"}],"version-history":[{"count":0,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/6549\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media\/6550"}],"wp:attachment":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media?parent=6549"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/categories?post=6549"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/tags?post=6549"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}