{"id":6378,"date":"2011-09-21T06:00:39","date_gmt":"2011-09-21T04:00:39","guid":{"rendered":"https:\/\/www.plombiers-reunis.com\/v2\/?p=6378"},"modified":"2011-09-21T06:00:39","modified_gmt":"2011-09-21T04:00:39","slug":"retour-dexperience-sur-wc-raccorde-sur-evacuation-de-o75","status":"publish","type":"post","link":"https:\/\/plombiers-reunis.com\/v3\/evacuations\/wc\/retour-dexperience-sur-wc-raccorde-sur-evacuation-de-o75.html","title":{"rendered":"Retour d&rsquo;experience sur WC raccord\u00e9 sur \u00e9vacuation de \u00d875"},"content":{"rendered":"\n<div class=\"wp-block-image\"><figure class=\"alignright\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/evacuations\/wc\/retour-dexperience-sur-wc-raccorde-sur-evacuation-de-o75.html\/attachment\/pipe-diametre_75\" rel=\"attachment wp-att-6380\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2011\/09\/pipe-diametre_75-150x150.jpg\" alt=\"Pipe point d'int\u00e9rrogation\" class=\"wp-image-6380\"\/><\/a><\/figure><\/div>\n\n\n\n<p>C&rsquo;est une question qui a d\u00e9j\u00e0 \u00e9t\u00e9 pos\u00e9 a plusieurs reprise sur le forum, quel est le diam\u00e8tre minimum de pour l&rsquo;\u00e9vacuation d&rsquo;un Wc, th\u00e9oriquement cette \u00e9vacuation peut \u00eatre r\u00e9alis\u00e9 en diam\u00e8tre \u00d880 a condition qu&rsquo;elle soit de longueur inf\u00e9rieur a 1 m\u00e8tre.<\/p>\n\n\n\n<p>Dans cette page je vais faire un retour d\u2019exp\u00e9rience sur le sujet&#8230;.<\/p>\n\n\n\n<!--more-->\n\n\n\n<h2 class=\"hrcolor wp-block-heading\">Retour d\u2019exp\u00e9rience sur \u00e9vacuation de \u00d875<\/h2>\n\n\n\n<p><span style=\"color: #ff0000;\">J&rsquo;ai longuement h\u00e9sit\u00e9 avant d&rsquo;\u00e9crire cet article, je ne voudrais pas enduire mes lecteurs en erreur, car ce type de r\u00e9alisations est contraire aux r\u00e8gles de bonne conduite des plombiers, simplement parce qu&rsquo;on n&rsquo;\u00e9vacue jamais un WC avec un diam\u00e8tre inf\u00e9rieur a 100.<\/span><\/p>\n\n\n\n<p>Vers le mois de d\u00e9cembre 2008 je me suis retrouv\u00e9 a changer un WC chez un client&#8230; Pour moi, ainsi que pour la majorit\u00e9 des plombiers, le changement d&rsquo;un WC est une op\u00e9ration banale, il s&rsquo;agissait en fait d&rsquo;un WC porcher avec \u00e9vacuation de \u00d875 a aspiration (aspirambo).<\/p>\n\n\n\n<p>Avec mes 20 ans d\u2019exp\u00e9rience, je connaissait les \u00e9vacuations de \u00d875 entre la chute et le wc mais je n&rsquo;avais jamais vu une culotte de \u00d875 sur une chute, en g\u00e9n\u00e9ral la chute est en \u00d8 100 ou 110 ainsi que la culotte, puis il y a une ou plusieurs r\u00e9ductions pour permettre le branchement de la partie en \u00d875.<\/p>\n\n\n\n<p>Dans ce cas pr\u00e9cis, lorsque j&rsquo;ai ouvert la gaine technique pour le remplacement des tuyaux en \u00d8 75 par des tuyaux en \u00d8 100 j&rsquo;ai remarqu\u00e9 que la culotte \u00e9tait aussi en diam\u00e8tre 75 sur la chute d\u2019o\u00f9 l&rsquo;obligation de garder une partie de petit diam\u00e8tre, ce qui est vraiment du bricolage.<\/p>\n\n\n\n<p>Apres avoir discut\u00e9 avec le client et l&rsquo;avoir inform\u00e9 des risque encourus, il ma dit de poser quand m\u00eame le WC puis il s&rsquo;adresserait au syndic en cas de probl\u00e8me pour le remplacement de la culotte sur la chute afin de lui permettre d\u2019\u00e9vacuer correctement son Wc.&nbsp;<em>Donc j&rsquo;ai pos\u00e9 le WC et je suis parti<\/em>.<\/p>\n\n\n\n<h2 class=\"hrcolor wp-block-heading\">Fiabilit\u00e9 dans le temps, combien de temps avant que \u00e7a se bouche?<\/h2>\n\n\n\n<p>A vrais dire je m&rsquo;attendais a ce que ce client appelle l&rsquo;entreprise pour signaler les dysfonctionnements, ou alors a que son syndic d&rsquo;immeuble se r\u00e9volte contre mon employeur parce que ce Wc se bouche a r\u00e9p\u00e9tition, a ma grande surprise il ne fut rien&nbsp;<strong>il ne s&rsquo;est jamais bouch\u00e9<\/strong>&nbsp;depuis bient\u00f4t 3 ans.<\/p>\n\n\n\n<p>Pour cette r\u00e9alisation, il aurait fallu utiliser un tube d&rsquo;\u00e9vacuation de la m\u00eame section que celui qui \u00e9tait d\u00e9j\u00e0 en place avec une pipe point d&rsquo;interrogation de diam\u00e8tre 75 visible en haut de page, mais comme je n&rsquo;avait pas ces raccords et ils sont difficiles a trouver.<\/p>\n\n\n\n<p>Je me suis donc permis de raccorder une \u00e9vacuation standard sur la culotte et le coude de \u00d875, en utilisant les raccords que j&rsquo;avais sous la main y compris un raccord ZTT pour adapter la r\u00e9duction conique que j&rsquo;ai pris soin d&rsquo;utiliser afin de limiter les risques d\u2019engorgement et favoriser la bonne \u00e9vacuation.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/evacuations\/wc\/retour-dexperience-sur-wc-raccorde-sur-evacuation-de-o75.html\/attachment\/wc-evcuee-en_75\" rel=\"attachment wp-att-6381\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"480\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2011\/09\/wc-evcuee-en_75.jpg\" alt=\"\u00e9vacuation PVC \u00d875\" class=\"wp-image-6381\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2011\/09\/wc-evcuee-en_75.jpg 640w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2011\/09\/wc-evcuee-en_75-300x225.jpg 300w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>Bien que je ne conseille pas ce type de raccordements, parfois on est vraiment oblig\u00e9 car on ne peut pas faire autrement, toutefois si cela vous arrive veillez tout de m\u00eame a ce que les tuyaux soient propres a l&rsquo;int\u00e9rieur, a ce qu&rsquo;il n&rsquo;y ai pas du calcaire a l&rsquo;int\u00e9rieur des tuyaux, comme d\u00e9crit dans l&rsquo;image suivante.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/evacuations\/wc\/retour-dexperience-sur-wc-raccorde-sur-evacuation-de-o75.html\/attachment\/evacuation-propre\" rel=\"attachment wp-att-6379\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"480\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2011\/09\/evacuation-propre.jpg\" alt=\"Evacuation propre\" class=\"wp-image-6379\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2011\/09\/evacuation-propre.jpg 640w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2011\/09\/evacuation-propre-300x225.jpg 300w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>Il arrive parfois que les tuyaux PVC soient tr\u00e8s entartr\u00e9s a l\u2019int\u00e9rieur, notamment sur l&rsquo;angle de la chute avec la culotte, c&rsquo;est en endroit particuli\u00e8rement sensible aux d\u00e9p\u00f4ts de tartre<\/p>\n","protected":false},"excerpt":{"rendered":"<p>C&rsquo;est une question qui a d\u00e9j\u00e0 \u00e9t\u00e9 pos\u00e9 a plusieurs reprise sur le forum, quel est le diam\u00e8tre minimum de pour l&rsquo;\u00e9vacuation d&rsquo;un Wc, th\u00e9oriquement cette \u00e9vacuation peut \u00eatre r\u00e9alis\u00e9 en diam\u00e8tre \u00d880 a condition qu&rsquo;elle soit de longueur inf\u00e9rieur a 1 m\u00e8tre. Dans cette page je vais faire un retour d\u2019exp\u00e9rience sur le sujet&#8230;.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"categories":[35],"tags":[],"class_list":["post-6378","post","type-post","status-publish","format-standard","hentry","category-wc"],"_links":{"self":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/6378","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/comments?post=6378"}],"version-history":[{"count":0,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/6378\/revisions"}],"wp:attachment":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media?parent=6378"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/categories?post=6378"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/tags?post=6378"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}