{"id":6255,"date":"2012-05-11T06:00:35","date_gmt":"2012-05-11T04:00:35","guid":{"rendered":"https:\/\/www.plombiers-reunis.com\/v2\/?p=6255"},"modified":"2025-11-23T19:39:10","modified_gmt":"2025-11-23T18:39:10","slug":"les-vannes-trois-et-quatre-voies-ou-vannes-de-melange","status":"publish","type":"post","link":"https:\/\/plombiers-reunis.com\/v3\/accessoires-chauffage\/les-vannes-trois-et-quatre-voies-ou-vannes-de-melange.html","title":{"rendered":"Les vannes trois et quatre voies ou vannes de m\u00e9lange"},"content":{"rendered":"\n<p>Les vannes 3 voies comprennent 3 orifices. Elles obturent alternativement 2 orifices sur 3, le troisi\u00e8me orifice appel\u00e9 voie commune restant toujours ouvert.<br>Elles peuvent jouer plusieurs r\u00f4les:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Le m\u00e9lange de deux fluides<\/li>\n\n\n\n<li>La commutation<\/li>\n\n\n\n<li>La r\u00e9partition<\/li>\n\n\n\n<li>La d\u00e9rivation<\/li>\n<\/ul>\n\n\n\n<p>Les possibilit\u00e9s sont nombreuses selon les besoins de chacun, elle peuvent \u00eatre install\u00e9s dans diff\u00e9rentes configurations. Ici nous allons parler de la fonction qui nos int\u00e9resse,&nbsp;<strong>le m\u00e9lange<\/strong>:&nbsp;<ins>utilis\u00e9 sur les circuits de chauffage.<\/ins><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">La vanne trois voies indispensable<\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/accessoires-chauffage\/les-vannes-trois-et-quatre-voies-ou-vannes-de-melange.html\/attachment\/trois-voies\" rel=\"attachment wp-att-6257\"><img loading=\"lazy\" decoding=\"async\" width=\"170\" height=\"125\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/10\/trois-voies.jpg\" alt=\"La vanne trois voies\" class=\"wp-image-6257\"\/><\/a><\/figure>\n<\/div>\n\n\n<p>La quasi totalit\u00e9 des installations anciennes avec chaudi\u00e8re de sol (mazoute) en sont \u00e9quip\u00e9s la vanne trois voies est un composant des plus importants de l&rsquo;installation, c&rsquo;est sur cet \u00e9l\u00e9ment que nous r\u00e9glons la temp\u00e9rature de d\u00e9part du fluide vers les radiateurs, en g\u00e9n\u00e9ral ce r\u00e9glage se fait manuellement, plus la temp\u00e9rature ext\u00e9rieur baisse et plus on doit ouvrir la vanne de m\u00e9lange sur le circuit principal.<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u00a0Les br\u00fbleurs plus anciens n\u2019ont qu&rsquo;un seule vitesse de fonctionnement, soit ils sont allum\u00e9s ou \u00e9teins, donc ils produisent toujours un chauffage a temp\u00e9rature tr\u00e8s \u00e9lev\u00e9 particuli\u00e8rement en p\u00e9riodes avec temp\u00e9rature ext\u00e9rieurs douce.<\/li>\n\n\n\n<li>Les br\u00fbleurs plus modernes sont d\u00e9j\u00e0 plus sophistiqu\u00e9s et sont munis de deux vitesses, donc ils on d\u00e9j\u00e0 la possibilit\u00e9 de produire plus ou moins en fonction des besoins.<\/li>\n\n\n\n<li>Les br\u00fbleurs actuels de haut de gamme sont d\u00e9j\u00e0 munis de 4 vitesses (certains mod\u00e8les) donc ils adaptent quasiment la production a la demande.<\/li>\n<\/ol>\n\n\n\n<p>Les br\u00fbleurs multi-vitesses sont forcement pilot\u00e9s par une r\u00e9gulation externe ou interne a la chaudi\u00e8re.<\/p>\n\n\n\n<p>Lors de l&rsquo;utilisation d&rsquo;une r\u00e9gulation avec action sur vanne, celle ci doit forcement \u00eatre motoris\u00e9 donc automatique,&nbsp;la r\u00e9gulation&nbsp;ouvre ou ferme la vanne de mani\u00e8re a obtenir la temp\u00e9rature de d\u00e9part ad\u00e9quate pour chauffer id\u00e9alement le local, pour permettre cette ouverture ou fermeture la r\u00e9gulation se r\u00e9f\u00e8re a une&nbsp;temp\u00e9rature pr\u00e9lev\u00e9 sur le tube de d\u00e9part au moins 50 cm apr\u00e8s la vanne de m\u00e9lange.<\/p>\n\n\n\n<p>Les vannes trois voies permettent de m\u00e9langer une partie de l&rsquo;eau qui reviens vers la chaudi\u00e8re a celle qui part vers les radiateurs afin d&rsquo;obtenir la temp\u00e9rature souhait\u00e9, si la temp\u00e9rature du retour est aussi elev\u00e9 que celle demand\u00e9 par la r\u00e9gulation, la vanne se ferme totalement, ce qui emp\u00eache l&rsquo;eau de la chaudi\u00e8re de circuler, donc l&rsquo;arr\u00eat de la chaudi\u00e8re.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Les vannes 4 voies<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/accessoires-chauffage\/les-vannes-trois-et-quatre-voies-ou-vannes-de-melange.html\/attachment\/vanne4voies\" rel=\"attachment wp-att-6258\"><img loading=\"lazy\" decoding=\"async\" width=\"280\" height=\"280\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/10\/vanne4voies.jpg\" alt=\"vanne 4 voies\" class=\"wp-image-6258\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/10\/vanne4voies.jpg 280w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/10\/vanne4voies-250x250.jpg 250w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/10\/vanne4voies-150x150.jpg 150w\" sizes=\"auto, (max-width: 280px) 100vw, 280px\" \/><\/a><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/accessoires-chauffage\/les-vannes-trois-et-quatre-voies-ou-vannes-de-melange.html\/attachment\/schema-vanne-4-voies\" rel=\"attachment wp-att-6256\"><img loading=\"lazy\" decoding=\"async\" width=\"237\" height=\"300\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/10\/schema-vanne-4-voies-237x300.jpg\" alt=\"Sch\u00e9ma de vanne 4 voies\" class=\"wp-image-6256\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/10\/schema-vanne-4-voies-237x300.jpg 237w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/10\/schema-vanne-4-voies.jpg 280w\" sizes=\"auto, (max-width: 237px) 100vw, 237px\" \/><\/a><\/figure>\n<\/div>\n\n\n<p>&nbsp; &nbsp;<\/p>\n\n\n\n<p>Les vannes 4 voies fonctionnent de la m\u00eame mani\u00e8re que les trois voies mais en plus elles permettent de m\u00e9langeur une partie de l&rsquo;eau sortante de la chaudi\u00e8re a celle qui viens des radiateurs, ceci afin de limiter l&rsquo;usure de la chaudi\u00e8re par l&rsquo;entr\u00e9 d&rsquo;une eau ti\u00e8de sur une corps de chauffe qui lui est a haute temp\u00e9rature.<\/p>\n\n\n\n<p>&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Le point de ros\u00e9<\/h3>\n\n\n\n<p>Sur l&rsquo;image d\u2019illustration, on aper\u00e7ois un circuit pointill\u00e9 sur le retour, c&rsquo;est la diff\u00e9rence entre la vanne 3 et 4 voies, sur ce sch\u00e9ma c&rsquo;est donc l&rsquo;eau du retour a laquelle un peut d&rsquo;eau du d\u00e9part est m\u00e9lang\u00e9 afin que l&rsquo;eau ne rentre pas trop froide sur la chaudi\u00e8re.<\/p>\n\n\n\n<p>Ce ph\u00e9nom\u00e8ne d\u00e9crit juste au dessus s\u2019appelle le point ros\u00e9 qui est tr\u00e8s mal support\u00e9 par les chaudi\u00e8res anciennes,&nbsp;<strong>le point ros\u00e9&nbsp;<\/strong>provoque une corrosion acc\u00e9l\u00e9r\u00e9 du corps de chauffe, usure en quelques ann\u00e9es seulement.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Les vannes 3 voies comprennent 3 orifices. Elles obturent alternativement 2 orifices sur 3, le troisi\u00e8me orifice appel\u00e9 voie commune restant toujours ouvert.Elles peuvent jouer plusieurs r\u00f4les: Les possibilit\u00e9s sont nombreuses selon les besoins de chacun, elle peuvent \u00eatre install\u00e9s dans diff\u00e9rentes configurations. Ici nous allons parler de la fonction qui nos int\u00e9resse,&nbsp;le m\u00e9lange:&nbsp;utilis\u00e9 sur &#8230; <a title=\"Les vannes trois et quatre voies ou vannes de m\u00e9lange\" class=\"read-more\" href=\"https:\/\/plombiers-reunis.com\/v3\/accessoires-chauffage\/les-vannes-trois-et-quatre-voies-ou-vannes-de-melange.html\" aria-label=\"En savoir plus sur Les vannes trois et quatre voies ou vannes de m\u00e9lange\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":6258,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"categories":[2],"tags":[],"class_list":["post-6255","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-accessoires-chauffage"],"_links":{"self":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/6255","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/comments?post=6255"}],"version-history":[{"count":0,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/6255\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media\/6258"}],"wp:attachment":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media?parent=6255"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/categories?post=6255"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/tags?post=6255"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}