{"id":6029,"date":"2005-09-10T06:00:19","date_gmt":"2005-09-10T04:00:19","guid":{"rendered":"https:\/\/www.plombiers-reunis.com\/v2\/?p=6029"},"modified":"2005-09-10T06:00:19","modified_gmt":"2005-09-10T04:00:19","slug":"la-ventilation-des-locaux-vmc","status":"publish","type":"post","link":"https:\/\/plombiers-reunis.com\/v3\/isolation-ventilation\/la-ventilation-des-locaux-vmc.html","title":{"rendered":"La ventilation des locaux (VMC)"},"content":{"rendered":"\n<p>La ventilation consiste a renouveler l\u2019air vici\u00e9 dans les espaces habitables, cette ventilation est indispensable a notre sant\u00e9.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"\/v3\/#naturelle\">La ventilation naturelle<\/a>, encore pr\u00e9sente dans beaucoup d&rsquo;immeubles<\/li>\n\n\n\n<li><a href=\"\/v3\/#consequences\">Les cons\u00e9quences du manque de ventilation<\/a><\/li>\n\n\n\n<li><a href=\"\/v3\/#obligatoire\">La ventilation rendue obligatoire en 1982<\/a><\/li>\n\n\n\n<li><a href=\"\/v3\/#vmc\">La VMC \u00ab\u00a0ventilation m\u00e9canique contr\u00f4l\u00e9\u00a0\u00bb<\/a><\/li>\n\n\n\n<li><a href=\"\/v3\/#debits\">Les d\u00e9bits obligatoires<\/a><\/li>\n\n\n\n<li><a href=\"\/v3\/#rt2005\">La RT  2005<\/a><\/li>\n\n\n\n<li><a href=\"\/v3\/#rt2012\">La RT 2012<\/a><\/li>\n<\/ul>\n\n\n\n<!--more-->\n\n\n\n<p>Beaucoup de normes se sont succ\u00e9d\u00e9s au fils des ann\u00e9es afin de rendre notre qualit\u00e9 de vie meilleure mais aussi de rendre les ventilation plus efficaces, et plus derni\u00e8rement plus \u00e9conomes.<\/p>\n\n\n\n<p><span style=\"color: #ff0000;\">Cette page sera mise a jour au fil du temps en fonction des nouvelles technologies.<\/span><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"naturelle\">Ventilation d&rsquo;origine, la ventilation naturelle <\/h2>\n\n\n\n<p class=\"has-text-align-right\"><a href=\"\/v3\/#top\">\u2191<\/a><\/p>\n\n\n\n<p>Autrefois, on ventilait nos logements pas thermodynamie, ce que l&rsquo;on appelait la ventilation naturelle. Une conduite d&rsquo;air frais alimentait en air frais,&nbsp; les pi\u00e8ces humides avec une grille a environ 30 cm du sol.<\/p>\n\n\n\n<p>Ensuite une seconde conduite aspirait l&rsquo;air vici\u00e9 a l&rsquo;aide d&rsquo;une grille en partie sup\u00e9rieure&nbsp; des pi\u00e8ces humides, seules les pi\u00e8ces humides \u00e9taient pr\u00e9vues pour \u00eatre ventil\u00e9s<\/p>\n\n\n\n<p>Il faut se dire que les logements n&rsquo;\u00e9taient pas herm\u00e9tiques du tout.&nbsp;Fentes et nids \u00e0 courant d\u2019air garantissaient toujours une ventilation certes suffisante, mais au prix d\u2019un grand gaspillage inutile d\u2019\u00e9nergie.<\/p>\n\n\n\n<p>La crise de l\u2019\u00e9nergie de 1973 a r\u00e9volutionn\u00e9 cette situation. Les prix \u00e9lev\u00e9s des moyens \u00e9nerg\u00e9tiques (et les exigences plus strictes sur la protection de l\u2019environnement) ont provoqu\u00e9 un v\u00e9ritable mouvement d\u00e9ferlent vers l\u2019isolation.<\/p>\n\n\n\n<p>Les habitations modernes seront d\u00e8s lors tellement isol\u00e9es que, sans ventilation, la moindre particule d\u2019air ne peut plus s\u2019\u00e9chapper. Et d\u00e8s lors que la chaleur ne peut plus sortir, l\u2019air frais de l\u2019ext\u00e9rieur ne peut plus entrer.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"consequences\">Cons\u00e9quences du manque de ventilation<\/h2>\n\n\n\n<p class=\"has-text-align-right\"><a href=\"\/v3\/#top\">\u2191<\/a><\/p>\n\n\n\n<p><strong>Cons\u00e9quences:<\/strong>&nbsp;un climat int\u00e9rieur humide, avec des odeurs malsaines de renferm\u00e9, terrain propice aux moisissures et aux mites.<\/p>\n\n\n\n<p>Sans ventilation surgissent rapidement diff\u00e9rents probl\u00e8mes qui ont une influence sur notre bien-\u00eatre et notre sant\u00e9. Car, l\u00e0 o\u00f9 on habite, on respire, on fait la cuisine, on chauffe, on se lave, on prend des douches \u2026<\/p>\n\n\n\n<p>Une famille moyenne produit de cette mani\u00e8re de 14 \u00e0 20 litres d\u2019humidit\u00e9 en vingt-quatre heures, comme toutes sortes de poussi\u00e8res d\u2019ailleurs (souvent nuisibles) provenant des v\u00eatements, des literies, des tapis, du parquet, des journaux et des cigarettes.<\/p>\n\n\n\n<p>Dans une telle atmosph\u00e8re, un grand nombre de moisissures et de vermine ont la voie libre pour se d\u00e9velopper, tandis que des odeurs de cuisson, de cigarette, d\u2019animaux domestiques restent en suspension dans la maison, persistantes des heures durant.<\/p>\n\n\n\n<p>Ennuis de sant\u00e9 caus\u00e9s par les \u00ab acariens \u00bb: Dans une maison mal ventil\u00e9e, les personnes sensibles au niveau du syst\u00e8me respiratoire (de 5 \u00e0 20% de la population) souffrent rapidement d\u2019ennuis de sant\u00e9. Compte tenu d\u2019une forte isolation, le nombre d\u2019acariens a d\u00e9cupl\u00e9 ces 25 derni\u00e8res ann\u00e9es.<\/p>\n\n\n\n<p>Le nombre des patients asthmatiques a doubl\u00e9 ces 15 derni\u00e8res ann\u00e9es.<\/p>\n\n\n\n<p>Une enqu\u00eate effectu\u00e9e en Hollande par la Fondation pour le Traitement de l\u2019Asthme a d\u00e9montr\u00e9 que la lutte contre l\u2019humidit\u00e9 dans les habitations a fortement contribu\u00e9 \u00e0 la diminution des r\u00e9actions allergiques chez les personnes souffrant de maladies des voies respiratoires.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"obligatoire\">La ventilation rendue obligatoire<\/h2>\n\n\n\n<p class=\"has-text-align-right\"><a href=\"\/v3\/#top\">\u2191<\/a><\/p>\n\n\n\n<p>La ventilation est devenue donc une obligation l\u00e9gale (arr\u00eat\u00e9s du 24 mars 1982 et du 28 octobre 1983) pour tous les logements post\u00e9rieurs \u00e0 1982 , collectifs ou individuels .<\/p>\n\n\n\n<p>Elle doit satisfaire aux exigences suivantes: l\u2019a\u00e9ration doit \u00eatre g\u00e9n\u00e9rale et permanente, la circulation d\u2019air doit se faire depuis des entr\u00e9es d\u2019air situ\u00e9es dans les pi\u00e8ces principales jusqu\u2019\u00e0 des sorties, dans les pi\u00e8ces de service.<br>Des d\u00e9bits r\u00e9glementaires suivants sont exig\u00e9s.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"debits\">D\u00e9bits r\u00e9glementaires pour&nbsp; une ventilation efficace<\/h4>\n\n\n\n<p class=\"has-text-align-right\"><a href=\"\/v3\/#top\">\u2191<\/a><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th colspan=\"6\">D\u00e9bit d\u2019extraction d\u2019air en m\u00e8tres cubes\/heure \u2013 M\u00b3\/H sur logements sans appareils de combustion.<\/th><\/tr><\/thead><tbody><tr><th>&nbsp;<\/th><th colspan=\"5\"><center><br>Pi\u00e8ces a ventiler<\/center><\/th><\/tr><tr><td><center><br>Nombre de pi\u00e8ces dans la maison<\/center><\/td><td>D\u00e9bit total de la maison<\/td><td><center><br>Cuisine<\/center><\/td><td><center>Salle de bains, avec ou sans Wc<\/center><\/td><td><center>Salle d\u2019eau avec ou sans Wc<\/center><\/td><td><center>Cabinet de toilettes<\/center><\/td><\/tr><tr><td><center><br>1<\/center><\/td><td><center>35<\/center><\/td><td><center>20 m\u00b3<\/center><\/td><td>15m\u00b3<\/td><td><center>15 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><\/tr><tr><td><center>2<\/center><\/td><td><center>60<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><\/tr><tr><td><center>3<\/center><\/td><td><center>75<\/center><\/td><td><center>45 m\u00b3<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><\/tr><tr><td><center>4<\/center><\/td><td><center>90<\/center><\/td><td><center>45 m\u00b3<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><\/tr><tr><td><center>5<\/center><\/td><td><center>105<\/center><\/td><td><center>45 m\u00b3<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><\/tr><tr><td><center>6<\/center><\/td><td><center>120<\/center><\/td><td><center>45 m\u00b3<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><\/tr><tr><td><center>7<\/center><\/td><td><center>135<\/center><\/td><td><center>45 m\u00b3<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><td><center>15 m\u00b3<\/center><\/td><td><center>30 m\u00b3<\/center><\/td><\/tr><tr><td>&nbsp;<\/td><td colspan=\"6\"><center><em>D\u00e9bits minimaux en m\u00e8tres cubes a l\u2019heure<\/em><\/center><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>La fa\u00e7on la plus s\u00fbre de les obtenir ces quantit\u00e9s&nbsp; et de contr\u00f4ler a ne pas trop ventiler, est d\u2019installer une VMC.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"vmc\">Les Syst\u00e8mes de VMC<\/h2>\n\n\n\n<p class=\"has-text-align-right\"><a href=\"\/v3\/#top\">\u2191<\/a><\/p>\n\n\n\n<p>Les syst\u00e8mes VMC contr\u00f4lent en plus la quantit\u00e9 d\u2019air vici\u00e9 int\u00e9rieur, rejet\u00e9 \u00e0 l\u2019ext\u00e9rieur et l\u2019air frais ext\u00e9rieur amen\u00e9 \u00e0 l\u2019int\u00e9rieur du local.<\/p>\n\n\n\n<p>Le puits Canadien, est un circuit souterrain de longueur variable selon le logement a ventiler, ou l\u2019air circule avant de p\u00e9n\u00e9trer dans le local, ce qui permets une pr\u00e9-chauffe de l\u2019air, donc des \u00e9conomies de chauffage.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"rt2005\">Arriv\u00e9e de la RT 2005<\/h2>\n\n\n\n<p class=\"has-text-align-right\"><a href=\"\/v3\/#top\">\u2191<\/a><\/p>\n\n\n\n<p>La nouvelles r\u00e9glementation RT2005, oblige les fabricants a r\u00e9fl\u00e9chir et a am\u00e9liorer les syst\u00e8mes de ventilation, du coup des&nbsp; nouveaux syst\u00e8mes de ventilation font son apparition dans le commerce, la double flux et l&rsquo;hygror\u00e9glable.<\/p>\n\n\n\n<p>Les syst\u00e8mes de VMC double flux pr\u00e9-chauffent l\u2019air ext\u00e9rieur aspir\u00e9 vers le local en r\u00e9cup\u00e9rant les calories pr\u00e9sentes dans l\u2019air vici\u00e9 extrait vers l\u2019ext\u00e9rieur.<\/p>\n\n\n\n<p>Les VMC hygror\u00e9glable sont des moteurs d&rsquo;aspiration a r\u00e9gulation \u00e9lectronique de la vitesse de rotation ce qui permets de contr\u00f4ler tr\u00e8s pr\u00e9cis\u00e9ment le d\u00e9bit d&rsquo;air aspir\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"rt2012\">Arriv\u00e9e de la RT 2012<\/h2>\n\n\n\n<p class=\"has-text-align-right\"><a href=\"\/v3\/#top\">\u2191<\/a><\/p>\n\n\n\n<p>D\u00e9sormais seuls les syst\u00e8mes de ventilation hygror\u00e9glable sont compatibles avec cette derni\u00e8re norme.<\/p>\n\n\n\n<p>Ils int\u00e8grent aussi une sonde qui mesure l&rsquo;humidit\u00e9 contenue dans l&rsquo;air et la d\u00e9pression des locaux, mais en plus les bouches d&rsquo;aspiration sont intelligentes et font partie integrante du systeme. \u00ab\u00a0<em>Plus l&rsquo;air est humide et plus important sera le d\u00e9bit d&rsquo;aspiration\u00a0\u00bb.<\/em><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Les bouches d&rsquo;aspiration dans les cuisines<\/strong> (<em>avec piles<\/em>)\n<ul class=\"wp-block-list\">\n<li>Elles sont hygror\u00e9glables, en temps normal elles sont ferm\u00e9 a 90%<\/li>\n\n\n\n<li>Si le taux d&rsquo;humidit\u00e9 est sup\u00e9rieur a un seuil d\u00e9termine, la bouche s&rsquo;ouvre a 100%<\/li>\n\n\n\n<li>Un bouton poussoir permets d&rsquo;ouvrir la bouce en totalit\u00e9 avant m\u00eame qu&rsquo;elle detecte l&rsquo;humidit\u00e9.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Dans les WC<\/strong> (<em>avec piles<\/em>)\n<ul class=\"wp-block-list\">\n<li>Ces bouches sont munies de d\u00e9tecteurs de pr\u00e9sence<\/li>\n\n\n\n<li>En temps normal la bouche est ferme a 90%,<\/li>\n\n\n\n<li>Si une personne est d\u00e9tecte la bouche s&rsquo;ouvre a 100% pendant 30 mn apr\u00e8s le dernier mouvent d\u00e9tect\u00e9, pour se refermer ensuite.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>Dans les salles de bains, buanderies et locaux humides<\/strong> (<em>m\u00e9caniques<\/em>)\n<ul class=\"wp-block-list\">\n<li>L&rsquo;aspiration est permanente, le d\u00e9bit est r\u00e9gl\u00e9 par membrane qui detecte la d\u00e9pression du local, plus la d\u00e9pression est importante et plus la bouche se ferme.<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<p>Toutefois sir le taux d&rsquo;humidit\u00e9 est tr\u00e8s bas ou si la d\u00e9pression deviens importante,&nbsp; le d\u00e9bit d&rsquo;aspiration sera r\u00e9duit au minimum et cela quelle qu&rsquo;en soit la bouche d&rsquo;extraction utilis\u00e9.<\/p>\n\n\n\n<p>Ainsi les bouches hygroreglables, sont munies du m\u00eame systeme, si le taux d&rsquo;humidit\u00e9 est superieur a un sueil determin\u00e9, la bouche s&rsquo;ouvre a 100%, dans le cas contraire ett se ferme presque en totalit\u00e9<\/p>\n\n\n\n<p><strong>Grilles d\u2019apport d\u2019air ferm\u00e9es<\/strong>: En hiver, de nombreuses personnes ferment ou bouchent les grilles d\u2019entr\u00e9e d\u2019air plac\u00e9es dans les ch\u00e2ssis de fen\u00eatre, pour maintenir la chaleur \u00e0 l\u2019int\u00e9rieur des logements.<\/p>\n\n\n\n<p>De ce fait, l\u2019effet b\u00e9n\u00e9fique d\u2019un syst\u00e8me de ventilation est \u00e0 peu pr\u00e8s r\u00e9duit \u00e0 n\u00e9ant, avec toutes les cons\u00e9quences n\u00e9gatives sur le climat int\u00e9rieur de ces habitations.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>La ventilation consiste a renouveler l\u2019air vici\u00e9 dans les espaces habitables, cette ventilation est indispensable a notre sant\u00e9.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"categories":[16],"tags":[1405,1407,1409,1411],"class_list":["post-6029","post","type-post","status-publish","format-standard","hentry","category-isolation-ventilation","tag-ventilation","tag-ventilation-double-flux","tag-ventilation-force","tag-ventilation-mecanique"],"_links":{"self":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/6029","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/comments?post=6029"}],"version-history":[{"count":0,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/6029\/revisions"}],"wp:attachment":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media?parent=6029"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/categories?post=6029"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/tags?post=6029"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}