{"id":4804,"date":"2006-05-12T21:46:27","date_gmt":"2006-05-12T19:46:27","guid":{"rendered":"https:\/\/www.plombiers-reunis.com\/v2\/?p=4804"},"modified":"2006-05-12T21:46:27","modified_gmt":"2006-05-12T19:46:27","slug":"les-nourrices-de-distribution-pour-installations-pieuvre-et-sols-chauffants","status":"publish","type":"post","link":"https:\/\/plombiers-reunis.com\/v3\/reseaux\/les-nourrices-de-distribution-pour-installations-pieuvre-et-sols-chauffants.html","title":{"rendered":"Les nourrices de distribution pour installations pieuvre et sols chauffants"},"content":{"rendered":"<p>Les nourrices sont la distribution des installations pieuvre, quelque soit le mat\u00e9riel utilis\u00e9 (<em>cuivre recuit, PER ou multicouche<\/em>) pour la distribution&#8230; De moment que l&rsquo;installation est de type pieuvre, la nourrice est indispensable. Certains l\u2019appellent diff\u00e9remment: Nourrice, clarinette, centrale distribution etc&#8230;<\/p>\n<p>G\u00e9n\u00e9ralement sur installations (pieuvre)\u00a0 en cuivre soud\u00e9 ont fabrique la nourrice sur place en cuivre aussi, afin de supprimer les joints&#8230; donc ici nous allons parler essentiellement de nourrices per et multicouche.<!--more--><\/p>\n<p>Je pense l&rsquo;avoir d\u00e9j\u00e0 dit dans la page consacr\u00e9 au PER\u00a0mais je le r\u00e9p\u00e8te ici: Les tuyaux\u00a0PER\u00a0sont normalement r\u00e9serv\u00e9s aux installations encastr\u00e9s a 100% je partage ici deux images des nourrices d&rsquo;une installation dans un pays voisin.<\/p>\n<table style=\"border: 1px solid #DFDFDF;\">\n<tbody>\n<tr>\n<th>Avant passage des tuyaux<\/th>\n<th>Apr\u00e8s passage des tuyaux<\/th>\n<\/tr>\n<tr>\n<td style=\"texte-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4805 size-medium\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/attentes_reseau-300x200.jpg\" alt=\"Avant passage des tuyaux\" width=\"300\" height=\"200\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/attentes_reseau-300x200.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/attentes_reseau.jpg 350w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<td style=\"texte-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4816 size-medium aligncenter\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/per_nourrices-300x200.jpg\" alt=\"Apres passage des tuyaux\" width=\"300\" height=\"200\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/per_nourrices-300x200.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/per_nourrices.jpg 350w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Force est de constater que \u00e7a n&rsquo;a rien a voir avec ce que nous faisons en France, ceci sur les installation PER.<\/p>\n<h2>De quel diam\u00e8tre doit \u00eatre\u00a0ma nourrice?\u200b<\/h2>\n<p>Les diam\u00e8tres\u00a0des composants de plomberie sont\u00a0mesur\u00e9s en DN (diam\u00e8tre nominal) ce qui \u00e9quivaut au diam\u00e8tre\u00a0nominal de passage sur l&rsquo;int\u00e9gralit\u00e9 du composant, on conviens\u00a0donc\u00a0qu&rsquo;il faut\u00a0prendre une nourrice avec\u00a0un diam\u00e8tre\u00a0au moins\u00a0\u00e9gal a celui\u00a0du tuyau qui l&rsquo;alimente, voir m\u00eame\u00a0sup\u00e9rieur\u00a0(<em>jamais inf\u00e9rieur<\/em>).<\/p>\n<p>On convient\u00a0alors\u00a0que les nourrices\u00a020\/27 avec des sorties 15\/21 conviennent pour la majorit\u00e9 des installations individuelles\u00a0gr\u00e2ce a son\u00a0diam\u00e8tre\u00a0nominal de 20mm\u00a0sur la distribution et son diam\u00e8tre\u00a0nominal de 15mm sur les sorties.<\/p>\n<h2>Les diff\u00e9rents type de nourrices<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-4813 alignright\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/Nourrice_simple-150x97.jpg\" alt=\"\" width=\"150\" height=\"97\" \/>Premi\u00e8rement on trouve les nourrices normales que tout le monde conna\u00eet en taille 3\/4 (20\/27) et sorties en 1\/2 (15\/21).<a href=\"https:\/\/plombiers-reunis.com\/v3\/reseaux\/les-diametres-les-filetages-et-la-table-de-conversion.html\">.Voir la page diam\u00e8tres<\/a>.<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-4809 size-full\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/nourrice-glissement.gif\" alt=\"\" width=\"217\" height=\"73\" \/><\/p>\n<p>Deuxi\u00e8mement on trouve les nourrices en 3\/4 (20\/27) et sorties en 10mm et 16mm r\u00e9serv\u00e9 au per, nourrices a sertir directement avec une pince a glissement (AXIAL).<a href=\"https:\/\/plombiers-reunis.com\/v3\/reseaux\/le-choix-des-raccords-pour-tubes-per-et-multicouche.html\">Voir page raccords.<\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-4810\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/Nourrice_avec_vannes-150x150.jpg\" alt=\"\" width=\"220\" height=\"122\" \/><span style=\"font-size: 20px;\">Troisi\u00e8mement on trouve les nourrices avec des vannes int\u00e9gr\u00e9s, les tailles et diam\u00e8tres sont identiques aux concurrentes, il y a juste la mini-vanne en plus, je conseille fortement l&rsquo;utilisation de ce type de nourrices qui permets d&rsquo;isoler un appareil individuellement en cas de probl\u00e8me pour laisser tout le reste en service.<\/span><span style=\"font-size: 20px;\">\u00a0 \u00a0 \u00a0<\/span><\/p>\n<p>Ensuite nous avons les nourrices de type coniques, elles sont identiques a toutes les autres nourrices en taille et en diam\u00e8tres, <strong>sauf sur le point suivant:<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-4811 size-full\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/Nourrice_conique.jpg\" alt=\"\" width=\"278\" height=\"88\" \/><\/p>\n<p>elles n\u00e9cessitent l&rsquo;utilisation d&rsquo;une pi\u00e8ce sp\u00e9ciale au niveau de la sortie, on ne peut pas utiliser des joints avec ce type de nourrices, car leur port\u00e9 n&rsquo;est pas plate et donc non adapt\u00e9 a \u00eatre\u00a0utilis\u00e9 avec des joints..<\/p>\n<p><span style=\"font-size: 20px;\">Il conviens d&rsquo;acheter la nourrice et les adaptateurs de la m\u00eame marque sous peine d&rsquo;avoir des fuites pour cause d&rsquo;incompatibilit\u00e9.Dans l&rsquo;ordre d&rsquo;affiche nous trouvons: nourrice, bague per 12 et 16, bague multicouche, bague cuivre.<\/span><span style=\"font-size: 20px;\">\u00a0<\/span><\/p>\n<h2>Les nourrices artisanales<\/h2>\n<p>Si malgr\u00e9 tous les modeles de nourrices qui l&rsquo;on trouve dans le commerce, on ne trouve pas son bonheur, rien n\u2019emp\u00eache de les fabriquer soit m\u00eame avec de tuyaux de cuivre.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Nourrices pour sanitaire<\/th>\n<th>Nourrices pour chauffage<\/th>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/reseaux\/les-nourrices-de-distribution-pour-installations-pieuvre-et-sols-chauffants.html\/attachment\/dav-24\" rel=\"attachment wp-att-6043\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-6043 aligncenter\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2006\/05\/nourrice-eau-sanitaire-300x140.jpg\" alt=\"nourrices sanitaire\" width=\"300\" height=\"140\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2006\/05\/nourrice-eau-sanitaire-300x140.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2006\/05\/nourrice-eau-sanitaire-1024x478.jpg 1024w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2006\/05\/nourrice-eau-sanitaire-768x358.jpg 768w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2006\/05\/nourrice-eau-sanitaire.jpg 1200w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><br \/>\nDans le cas de fabrication artisanale, je conseille l&rsquo;utilisation des vannes sur chaque ligne.<\/td>\n<td style=\"width: 50%;\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/reseaux\/les-nourrices-de-distribution-pour-installations-pieuvre-et-sols-chauffants.html\/attachment\/dav-25\" rel=\"attachment wp-att-6044\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-6044 aligncenter\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2006\/05\/nourrices-chauffage-300x140.jpg\" alt=\"nourrices chauffage\" width=\"300\" height=\"140\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2006\/05\/nourrices-chauffage-300x140.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2006\/05\/nourrices-chauffage-1024x478.jpg 1024w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2006\/05\/nourrices-chauffage-768x358.jpg 768w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2006\/05\/nourrices-chauffage.jpg 1200w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><br \/>\nPour la distribution de chauffage, les vannes ne sont pas vraiment utiles, on peut donc \u00e9conomiser quelques dizaines d&rsquo;euros.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Les adaptateurs pour les sorties de nourrice<\/h2>\n<p>Ces adaptateurs existent sous plusieurs formes, ils sont diff\u00e9rents d&rsquo;une marque a l&rsquo;autre et certains ont un pas de vis sp\u00e9cifique qui n&rsquo;est pas du tout standard.<\/p>\n<p class=\"avert\">Afin de garder la compatibilit\u00e9 entre nourrices et raccords il est conseill\u00e9 d&rsquo;acheter les deux ensemble.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Bague pour tuyaux Cuivre<\/th>\n<th>Bague pour tuyaux PER<\/th>\n<th>BAgue pour tuyaux Multicouche<\/th>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-4806 alignnone\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/Bague_conique-150x104.jpg\" alt=\"\" width=\"150\" height=\"104\" \/><\/td>\n<td>\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-4808 alignnone\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/Bague_thorique-150x111.jpg\" alt=\"\" width=\"150\" height=\"111\" \/><\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"size-thumbnail wp-image-4807 alignnone\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/bague_porte_conique-150x108.jpg\" alt=\"\" width=\"150\" height=\"108\" \/><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<table>\n<tbody>\n<tr>\n<td>\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4819\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/bague-per-sur-nourrice-150x150.jpg\" alt=\"\" width=\"200\" height=\"103\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/bague-per-sur-nourrice-300x154.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/bague-per-sur-nourrice-1024x527.jpg 1024w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/bague-per-sur-nourrice-768x395.jpg 768w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/bague-per-sur-nourrice.jpg 1200w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/td>\n<td>\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-4818\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/raccorder-per-sur-nourrices-150x150.jpg\" alt=\"\" width=\"200\" height=\"103\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/raccorder-per-sur-nourrices-300x154.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/raccorder-per-sur-nourrices-1024x527.jpg 1024w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/raccorder-per-sur-nourrices-768x395.jpg 768w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/raccorder-per-sur-nourrices.jpg 1200w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Nourrices pour sols chauffants<\/h2>\n<p>Ensuite on pr\u00e9sente ici les nourrices pour sol chauffant elles existent de plusieurs formes et tailles selon le nombre de serpentins a alimenter, elles peuvent \u00eatre manuelles a 100%, thermostatiques ou encore motoris\u00e9s avec des vannes qui r\u00e8glent le d\u00e9bit selon la commande d&rsquo;un thermostat ou r\u00e9gulation.<\/p>\n<p>Dans les images suivantes, on trouve tout d&rsquo;abord une nourrice de chauffage basique\u00a0 puis une nourrice de sol chauffant.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Nourrice Radiateurs<\/th>\n<th>Nourrice plancher chauffant<\/th>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4812 alignnone\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/Nourrice_plancher_chauffant-300x206.jpg\" alt=\"nourrice radiateurs\" width=\"300\" height=\"206\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/Nourrice_plancher_chauffant-300x206.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/Nourrice_plancher_chauffant.jpg 379w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4814 size-medium\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/Nourrice_solchauffant_thermostat-300x196.jpg\" alt=\"nourrice plancher chauffant\" width=\"300\" height=\"196\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/Nourrice_solchauffant_thermostat-300x196.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/Nourrice_solchauffant_thermostat.jpg 397w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-size: 20px;\">On constate que les nourrices Radiateurs\u00a0 sont d\u00e9munies de r\u00e9glages individuelles sur chaque sortie, alors que dans la seconde image on voit que les nourrices sont munies de r\u00e9glages. sur toutes les sorties.<\/span><\/p>\n<p><span style=\"font-size: 20px;\">Nous trouvons ici un exemple d&rsquo;une nourrice de sol chauffant en situation.<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-4820 size-medium alignnone\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/nourrices-plancher-chauffant-1-300x169.jpg\" alt=\"\" width=\"300\" height=\"169\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/nourrices-plancher-chauffant-1-300x169.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/nourrices-plancher-chauffant-1-1024x576.jpg 1024w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/nourrices-plancher-chauffant-1-768x432.jpg 768w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/nourrices-plancher-chauffant-1.jpg 1200w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>\u00a0\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-4822\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2018\/05\/nourrices_plancher_chauffant-300x169.jpg\" alt=\"\" width=\"300\" height=\"169\" srcset=\"https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/nourrices_plancher_chauffant-300x169.jpg 300w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/nourrices_plancher_chauffant-768x432.jpg 768w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/nourrices_plancher_chauffant-1024x576.jpg 1024w, https:\/\/plombiers-reunis.com\/v3\/wp-content\/uploads\/2018\/05\/nourrices_plancher_chauffant.jpg 1200w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/span><\/p>\n<p><span style=\"font-size: 20px;\">Comme on peut le constater ces nourrices sont compl\u00e9t\u00e9s par des composants difficiles a\u00a0 trouver dans le commerce, voir m\u00eame introuvables dans les magasin de bricolage, cela pour la simple raison que:\u00a0<\/span><ins style=\"font-size: 20px;\">on ach\u00e8te pas les mat\u00e9riaux de sol chauffant en vrac dans les magasins pour r\u00e9aliser un chauffage par le sol il faut proc\u00e9der de la mani\u00e8re suivante.<\/ins><\/p>\n<p><span style=\"font-size: 20px;\">R\u00e9aliser une \u00e9tude de la pi\u00e8ce a chauffer, puis c&rsquo;est l&rsquo;\u00e9tude qui d\u00e9termine, le nombre de serpentins, les pas de passage des tuyaux, et le d\u00e9bit de chaque serpentin, il faut donc acheter son sol chauffant en kit.<\/span><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Les nourrices sont la distribution des installations pieuvre, quelque soit le mat\u00e9riel utilis\u00e9 (cuivre recuit, PER ou multicouche) pour la distribution&#8230; De moment que l&rsquo;installation est de type pieuvre, la nourrice est indispensable. Certains l\u2019appellent diff\u00e9remment: Nourrice, clarinette, centrale distribution etc&#8230; G\u00e9n\u00e9ralement sur installations (pieuvre)\u00a0 en cuivre soud\u00e9 ont fabrique la nourrice sur place en &#8230; <a title=\"Les nourrices de distribution pour installations pieuvre et sols chauffants\" class=\"read-more\" href=\"https:\/\/plombiers-reunis.com\/v3\/reseaux\/les-nourrices-de-distribution-pour-installations-pieuvre-et-sols-chauffants.html\" aria-label=\"En savoir plus sur Les nourrices de distribution pour installations pieuvre et sols chauffants\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":4822,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"categories":[5],"tags":[238,910,1258],"class_list":["post-4804","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-reseaux","tag-chauffage-au-sol","tag-plancher-chauffant","tag-sol-radiant"],"_links":{"self":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/4804","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/comments?post=4804"}],"version-history":[{"count":0,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/4804\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media\/4822"}],"wp:attachment":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media?parent=4804"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/categories?post=4804"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/tags?post=4804"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}