{"id":3637,"date":"2010-04-29T22:31:00","date_gmt":"2010-04-29T22:31:00","guid":{"rendered":"http:\/\/www.lebriconaute.com\/installations\/dessin-de-tres-grande-installation-de-plomberie-et-chauffage.html"},"modified":"2010-04-29T22:31:00","modified_gmt":"2010-04-29T22:31:00","slug":"comprendre-les-temperatures-delta","status":"publish","type":"post","link":"https:\/\/plombiers-reunis.com\/v3\/chauffage\/les-radiateurs\/comprendre-les-temperatures-delta.html","title":{"rendered":"Comprendre les temp\u00e9ratures delta"},"content":{"rendered":"\n<p>Il existe plusieurs types de radiateurs: en fonte, en aluminium, en acier, en cuivre, puis d&rsquo;autres mod\u00e8les moins courants en r\u00e9sine graphit\u00e9 en verre en bois, etc&#8230;<\/p>\n\n\n\n<p>Il en existe de radiateurs haute temp\u00e9rature, classiques et basse temp\u00e9rature, d&rsquo;une mani\u00e8re g\u00e9n\u00e9rale, les radiateurs sont calcul\u00e9s (<em>sauf mention contraire<\/em>) a une temp\u00e9rature Delta T 50\u0394,  suite a la norme EN 442 qui est venu harmoniser tout \u00e7a.<\/p>\n\n\n\n<p>\u2022 90\/70  anciennes chaudi\u00e8res haute temp\u00e9rature<br>\u2022 75\/65 basse temp\u00e9rature  suite a la norme EN 442<br>\u2022 35\/27 tr\u00e8s basse temp\u00e9rature pour le chauffage surfacique<\/p>\n\n\n\n<!--more-->\n\n\n\n<h2 class=\"wp-block-heading\">Calcul de temp\u00e9rature Delta T<\/h2>\n\n\n\n<p class=\"astuce\">La temp\u00e9rature delta T se calcule de fa\u00e7on suivante: on adicione la temp\u00e9rature d&rsquo;ent\u00e9e et celle de sortie du radiateur et on divise par deux on soustrait la temp\u00e9rature c\u00e9d\u00e9 au local pour obtenir le r\u00e9sultat en delta T.<\/p>\n\n\n\n<p>Exemple de diff\u00e9rence entre un ancienne installation et une installation plus moderne a la norme EN 442.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/les-radiateurs\/comprendre-les-temperatures-delta.html\/attachment\/delta-80\" rel=\"attachment wp-att-5876\"><img loading=\"lazy\" decoding=\"async\" width=\"190\" height=\"142\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2010\/04\/delta-80.png\" alt=\"Delta 80\" class=\"wp-image-5876\"\/><\/a><\/figure>\n<\/div>\n\n\n<p class=\"twForbidden\"><strong>Ancienne installation haute temp\u00e9rature.<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Temp\u00e9rature d&rsquo;entr\u00e9e 90\u00b0C<\/li>\n\n\n\n<li>Temp\u00e9rature de sortie  70\u00b0C<\/li>\n\n\n\n<li>90\u00b0C + 70\u00b0C \/ 2 &#8211; 20\u00b0C = 60\u00b0C de temp\u00e9rature Delta T.<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright\"><a href=\"https:\/\/plombiers-reunis.com\/v3\/les-radiateurs\/comprendre-les-temperatures-delta.html\/attachment\/delta-60\" rel=\"attachment wp-att-5875\"><img loading=\"lazy\" decoding=\"async\" width=\"244\" height=\"142\" src=\"https:\/\/plombiers-reunis.com\/v3\/medias\/2010\/04\/delta-60.png\" alt=\"Delta 60\" class=\"wp-image-5875\"\/><\/a><\/figure>\n<\/div>\n\n\n<p><strong>Installation plus moderne.<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Temp\u00e9rature d&rsquo;entr\u00e9e 70\u00b0C<\/li>\n\n\n\n<li>Temp\u00e9rature de sortie 50\u00b0C<\/li>\n\n\n\n<li>70\u00b0C + 50\u00b0C \/ 2 &#8211; 20\u00b0C = 40\u00b0C de temp\u00e9rature Delta T.<\/li>\n<\/ul>\n\n\n\n<p>Pour fournir la m\u00eame puissance, la surface de chauffe du radiateur doit donc \u00eatre beaucoup plus importante.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Am\u00e9lioration et \u00e9conomies d\u2019\u00e9nergie<\/h2>\n\n\n\n<p>Dans ce dernier cas, <strong>si on isole les locaux,<\/strong> on gagnera en d\u00e9perdition, donc pour une temp\u00e9rature de d\u00e9part de 70\u00b0C et un retour a 60\u00b0C soit seulement un \u00e9cart de 10\u00b0C entre d\u00e9part et retour, on gagnera sensiblement en puissance restitu\u00e9, cet \u00e9cart est du aussi a la vitesse du fluide qui va circuler plus rapidement que dans les anciennes installations sans circulateur.<\/p>\n\n\n\n<p>C&rsquo;est aussi sur ce point que les syst\u00e8mes sont calcul\u00e9s, de nous jours, non seulement on baisse les temp\u00e9ratures de fonctionnement mais on perfectionne  aussi les syst\u00e8mes, qui fonctionnent de plus en plus avec des \u00e9carts moins importants et des vitesses de flux am\u00e9lior\u00e9s.<\/p>\n\n\n\n<p>\u2022 90\/70 anciennes chaudi\u00e8res haute temp\u00e9rature &#8211; \u00e9cart de 20\u00b0C<br>\u2022 75\/65 basse temp\u00e9rature suite a la norme EN 442 &#8211; \u00e9cart de 10\u00b0C<br>\u2022 35\/27 tr\u00e8s basse temp\u00e9rature pour le chauffage surfacique &#8211; \u00e9cart de 8\u00b0C<\/p>\n\n\n\n<p>Ces \u00e9carts de moins en moins importants, sont aussi obtenus avec l&rsquo;am\u00e9lioration des locaux a chauffer, isolation am\u00e9lior\u00e9, fen\u00eatres \u00e9tanches, ventilation ma\u00eetris\u00e9, tous ces facteurs jouent un role important dans l&rsquo;\u00e9conomie d\u2019\u00e9nergie.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ce qu&rsquo;il faut savoir avant d&rsquo;acheter ses radiateurs<\/h3>\n\n\n\n<p>De nos jours, les radiateurs sont fabriqu\u00e9s et annonc\u00e9s de sa puissance finale en watts, en fonction de la norme EN 442, soit avec un delta de 50 \u00b0C.<\/p>\n\n\n\n<p>Pour ces qui d\u00e9sirent utiliser des temp\u00e9ratures delta inf\u00e9rieurs au delta standard 50C\u00b0 il faut donc augmenter la taille du radiateur afin d&rsquo;obtenir la puissance requise.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Puissances des radiateurs avec temp\u00e9rature delta inf\u00e9rieure a 50C\u00b0<\/h3>\n\n\n\n<figure class=\"wp-block-table is-style-regular\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Delta<\/td><td class=\"has-text-align-center\" data-align=\"center\">Multiplier par<\/td><td class=\"has-text-align-center\" data-align=\"center\">Pourcentage <\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">45C\u00b0<\/td><td class=\"has-text-align-center\" data-align=\"center\">1,15<\/td><td class=\"has-text-align-center\" data-align=\"center\"> + 15%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">40C\u00b0<\/td><td class=\"has-text-align-center\" data-align=\"center\">1,32<\/td><td class=\"has-text-align-center\" data-align=\"center\">+ 32%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">35C\u00b0<\/td><td class=\"has-text-align-center\" data-align=\"center\">1,58<\/td><td class=\"has-text-align-center\" data-align=\"center\">+ 58%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">30C\u00b0<\/td><td class=\"has-text-align-center\" data-align=\"center\">1,92<\/td><td class=\"has-text-align-center\" data-align=\"center\">+ 92%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">20C\u00b0<\/td><td class=\"has-text-align-center\" data-align=\"center\">3,22<\/td><td class=\"has-text-align-center\" data-align=\"center\">+ 322%<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">10C\u00b0<\/td><td class=\"has-text-align-center\" data-align=\"center\">7,75<\/td><td class=\"has-text-align-center\" data-align=\"center\">+775%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>La plupart des fabricants indiquent les \u00e9missions de chaleur des radiateurs sur la base d&rsquo;un \u25b2T  50\u00b0C, avec le perfectionnement des chaudi\u00e8res (basse temp\u00e9rature et condensation) et de la circulation forc\u00e9 l\u2019\u00e9cart de temp\u00e9rature dans les radiateurs n&rsquo;est plus de 20C\u00b0 comme dans cet exemple, mais d&rsquo;environ 10C\u00b0 soit une eau qui rentre dans le radiateur a environ 55C\u00b0 et que en sorts a 45C\u00b0.<\/p>\n\n\n\n<p><ins>Prenons un exemple concret pour mieux comprendre.<\/ins><\/p>\n\n\n\n<p class=\"astuce has-background\" style=\"background-color:#bfedc9\">Dans ma pi\u00e8ce j&rsquo;ai besoin d&rsquo;un radiateur de 2500watts , mais comme il va fonctionner avec une temp\u00e9rature delta de 35C\u00b0, je multiplie donc donc sa puissance par 1,58 soit: <strong>2500 x 1,58 = 3950<\/strong>. &#8211; 3950 \u00e9tant la puissance du radiateur que je dois installer pour obtenir 2500 watts avec un delta de 35C\u00b0.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Le secret des \u00e9conomies d\u2019\u00e9nergie avec les temp\u00e9ratures delta.<\/h4>\n\n\n\n<p>Imaginons qu&rsquo;un local a besoin de 200 KW\/H par jour pour se maintenir a temp\u00e9rature ambiante, le secret de l\u2019\u00e9conomie et du confort peut \u00eatre r\u00e9alis\u00e9 comme il suit:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nous produisons ces 200 KW\/H sur les 24 heures soit 8.33 KW\/H, et nous avons une temp\u00e9rature harmonis\u00e9 sur toute la dur\u00e9.<\/li>\n\n\n\n<li>Nous produisons ces m\u00eames 200 KW\/H en 12 heures, soit 16.66 KW\/H, et nous avons un coup de chaleur pendant un temps donn\u00e9 et froids le reste du temps.<\/li>\n<\/ul>\n\n\n\n<p>Dans le cas de l&rsquo;hypoth\u00e8se n\u00b02, le g\u00e9n\u00e9rateur tournerait seulement pendant 12heures avec des temp\u00e9ratures beaucoup plus \u00e9lev\u00e9s.<br>\nCe qui est moins confortable, pour l&rsquo;usager et moins \u00e9conome en \u00e9nergie<\/p>\n\n\n\n<p>Ceci reprends encore le principe de fonctionnement le plus \u00e9conomique, diffuseur de grande taille et liquide colporteur le moins chaud possible, comme les sols chauffants.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Il existe plusieurs types de radiateurs: en fonte, en aluminium, en acier, en cuivre, puis d&rsquo;autres mod\u00e8les moins courants en r\u00e9sine graphit\u00e9 en verre en bois, etc&#8230; Il en existe de radiateurs haute temp\u00e9rature, classiques et basse temp\u00e9rature, d&rsquo;une mani\u00e8re g\u00e9n\u00e9rale, les radiateurs sont calcul\u00e9s (sauf mention contraire) a une temp\u00e9rature Delta T 50\u0394, suite &#8230; <a title=\"Comprendre les temp\u00e9ratures delta\" class=\"read-more\" href=\"https:\/\/plombiers-reunis.com\/v3\/chauffage\/les-radiateurs\/comprendre-les-temperatures-delta.html\" aria-label=\"En savoir plus sur Comprendre les temp\u00e9ratures delta\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":5876,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"categories":[18],"tags":[386,1071,1319],"class_list":["post-3637","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-les-radiateurs","tag-delta50","tag-radiateurs","tag-temperatures-delta"],"_links":{"self":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/3637","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/comments?post=3637"}],"version-history":[{"count":0,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/3637\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media\/5876"}],"wp:attachment":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media?parent=3637"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/categories?post=3637"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/tags?post=3637"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}