{"id":3622,"date":"2008-07-10T11:14:00","date_gmt":"2008-07-10T11:14:00","guid":{"rendered":"http:\/\/www.gobricoleur.com\/installations\/les-dbits-dair-a-assurer-pour-une-ventillation-efficace.html"},"modified":"2008-07-10T11:14:00","modified_gmt":"2008-07-10T11:14:00","slug":"les-debits-dair-a-assurer-pour-une-ventillation-efficace","status":"publish","type":"post","link":"https:\/\/plombiers-reunis.com\/v3\/isolation-ventilation\/les-debits-dair-a-assurer-pour-une-ventillation-efficace.html","title":{"rendered":"Les d\u00e9bits d&#039;air a assurer pour une ventillation efficace"},"content":{"rendered":"<p><strong>Arr\u00eat\u00e9 du 24 mars 1982 dispositions relatives \u00e0 l&rsquo;a\u00e9ration des logements:<\/strong><br \/>\nL&rsquo;a\u00e9ration des logements doit pouvoir \u00eatre g\u00e9n\u00e9rale et permanente au moins pendant la p\u00e9riode o\u00f9 la<br \/>\ntemp\u00e9rature ext\u00e9rieure oblige \u00e0 maintenir les fen\u00eatres ferm\u00e9es.<br \/>\nToutefois dans les b\u00e2timents soumis \u00e0 un isolement acoustique renforc\u00e9, en application de l&rsquo;arr\u00eat\u00e9 du 6 octobre 1978 , l&rsquo;a\u00e9ration doit pouvoir \u00eatre g\u00e9n\u00e9rale et permanente en toute saison.<br \/>\nLa circulation de l&rsquo;air doit pouvoir se faire principalement par entr\u00e9e d&rsquo;air dans les pi\u00e8ces principales et sortie dans les pi\u00e8ces de service.<br \/>\nLe syst\u00e8me d&rsquo;a\u00e9ration doit comporter :<\/p>\n<ul>\n<li>Des entr\u00e9es d&rsquo;air dans toutes les pi\u00e8ces principales, r\u00e9alis\u00e9es par des orifices en fa\u00e7ades, des<br \/>\nconduits \u00e0 fonctionnement naturel ou des dispositifs m\u00e9caniques .<\/li>\n<li>Des sorties d&rsquo;air dans les pi\u00e8ces de service, au moins dans les cuisines, les salles de bains ou de<br \/>\ndouches et les cabinets d&rsquo;aisances, r\u00e9alis\u00e9es par des conduits verticaux \u00e0 tirage naturel ou des<br \/>\ndispositifs m\u00e9caniques.<\/li>\n<\/ul>\n<p>En installation collective de ventilation, si une pi\u00e8ce de service poss\u00e8de une sortie d&rsquo;air m\u00e9canique, toutes les autres pi\u00e8ces de service doivent en poss\u00e9der une.<br \/>\nL&rsquo;air doit pouvoir circuler librement des pi\u00e8ces principales vers les pi\u00e8ces de service.<br \/>\nUne pi\u00e8ce \u00e0 la fois principale et de service, telle qu&rsquo;une chambre ayant un \u00e9quipement de cuisine, doit comporter une entr\u00e9e et une sortie d&rsquo;air, r\u00e9alis\u00e9es comme indiqu\u00e9 ci-dessus.<br \/>\nLe renouvellement de l&rsquo;air dans les locaux habit\u00e9s est une n\u00e9cessit\u00e9 qui se justifie suivant les trois besoins suivants :<\/p>\n<ul>\n<li>Besoin des occupants : le confort et l&rsquo;hygi\u00e8ne<\/li>\n<li>Besoin du b\u00e2ti : la p\u00e9rennit\u00e9 du b\u00e2ti<\/li>\n<li>Besoin des appreils \u00e0 combustion : la s\u00e9curit\u00e9 face aux appareils de combustion<\/li>\n<\/ul>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<th colspan=\"7\" scope=\"col\" bgcolor=\"#CCCCCC\"><center><br \/>\nD\u00e9bit d&rsquo;extraction d&rsquo;air en m\u00e8tres cubes\/heure &#8211; M\u00b3\/H<br \/>\nsur logements sans appareils de combustion.<\/center><\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\" scope=\"col\" bgcolor=\"#CCCCCC\"><\/th>\n<th colspan=\"5\" scope=\"col\" bgcolor=\"#CCCCCC\"><center><br \/>\nPi\u00e8ces a ventiler<\/center><\/th>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" bgcolor=\"#CCCCCC\" width=\"14%\"><center><br \/>\nNombre de pi\u00e8ces dans la maison<\/center><\/td>\n<td width=\"14%\">D\u00e9bit total de la maison<\/td>\n<td width=\"12%\"><center><br \/>\nCuisine<\/center><\/td>\n<td width=\"23%\"><center><br \/>\nSalle de bains, avec ou sans Wc<\/center><\/td>\n<td width=\"21%\"><center><br \/>\nSalle d&rsquo;eau avec ou sans Wc<\/center><\/td>\n<td><center><br \/>\nCabinet de toilettes<\/center><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#CCCCCC\"><center><br \/>\n1<\/center><\/td>\n<td><center><br \/>\n35<\/center><\/td>\n<td><center><br \/>\n20 m\u00b3<\/center><\/td>\n<td style=\"text-align: center;\">\u00a015m\u00b3<\/td>\n<td><center>15 m\u00b3\u00a0<\/center><\/td>\n<td><center><br \/>\n15 m\u00b3<\/center><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#CCCCCC\" height=\"26\"><center><br \/>\n2<\/center><\/td>\n<td><center><br \/>\n60<\/center><\/td>\n<td><center><br \/>\n30 m\u00b3<\/center><\/td>\n<td><center>15 m\u00b3\u00a0<\/center><\/td>\n<td><center><br \/>\n15 m\u00b3<\/center><\/td>\n<td><center><br \/>\n15 m\u00b3<\/center><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#CCCCCC\" height=\"26\"><center><br \/>\n3<\/center><\/td>\n<td><center><br \/>\n75<\/center><\/td>\n<td><center><br \/>\n45 m\u00b3<\/center><\/td>\n<td><center><br \/>\n30 m\u00b3<\/center><\/td>\n<td><center><br \/>\n15 m\u00b3<\/center><\/td>\n<td><center><br \/>\n15 m\u00b3<\/center><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#CCCCCC\" height=\"26\"><center><br \/>\n4<\/center><\/td>\n<td><center><br \/>\n90<\/center><\/td>\n<td><center><br \/>\n45 m\u00b3<\/center><\/td>\n<td><center><br \/>\n30 m\u00b3<\/center><\/td>\n<td><center><br \/>\n15 m\u00b3<\/center><\/td>\n<td><center>30 m\u00b3\u00a0<\/center><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#CCCCCC\" height=\"26\"><center><br \/>\n5<\/center><\/td>\n<td><center><br \/>\n105<\/center><\/td>\n<td><center><br \/>\n45 m\u00b3<\/center><\/td>\n<td><center><br \/>\n30 m\u00b3<\/center><\/td>\n<td><center>15 m\u00b3\u00a0<\/center><\/td>\n<td><center><br \/>\n30 m\u00b3<\/center><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#CCCCCC\" height=\"26\"><center><br \/>\n6<\/center><\/td>\n<td><center><br \/>\n120<\/center><\/td>\n<td><center><br \/>\n45 m\u00b3<\/center><\/td>\n<td><center>30 m\u00b3\u00a0<\/center><\/td>\n<td><center><br \/>\n15 m\u00b3<\/center><\/td>\n<td><center><br \/>\n30 m\u00b3<\/center><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#CCCCCC\" height=\"26\"><center><br \/>\n7<\/center><\/td>\n<td><center><br \/>\n135<\/center><\/td>\n<td><center><br \/>\n45 m\u00b3<\/center><\/td>\n<td><center><br \/>\n30 m\u00b3<\/center><\/td>\n<td><center><br \/>\n15 m\u00b3<\/center><\/td>\n<td><center><br \/>\n30 m\u00b3<\/center><\/td>\n<\/tr>\n<tr>\n<td bgcolor=\"#CCCCCC\" height=\"26\"><\/td>\n<td colspan=\"6\"><center><br \/>\nD\u00e9bits minimaux en m\u00e8tres cubes a l&rsquo;heure<\/center><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p class=\"wpematico_credit\">Ces donn\u00e9s sont valables dans les normes actuelles pour les logements neufs, pour les logement anciens avec ventilation naturelle, il faut au moins respecter la taille les grilles d&rsquo;origine, sans les obstruer.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Arr\u00eat\u00e9 du 24 mars 1982 dispositions relatives \u00e0 l&rsquo;a\u00e9ration des logements: L&rsquo;a\u00e9ration des logements doit pouvoir \u00eatre g\u00e9n\u00e9rale et permanente au moins pendant la p\u00e9riode o\u00f9 la temp\u00e9rature ext\u00e9rieure oblige \u00e0 maintenir les fen\u00eatres ferm\u00e9es. Toutefois dans les b\u00e2timents soumis \u00e0 un isolement acoustique renforc\u00e9, en application de l&rsquo;arr\u00eat\u00e9 du 6 octobre 1978 , l&rsquo;a\u00e9ration &#8230; <a title=\"Les d\u00e9bits d&#039;air a assurer pour une ventillation efficace\" class=\"read-more\" href=\"https:\/\/plombiers-reunis.com\/v3\/isolation-ventilation\/les-debits-dair-a-assurer-pour-une-ventillation-efficace.html\" aria-label=\"En savoir plus sur Les d\u00e9bits d&#039;air a assurer pour une ventillation efficace\">Lire la suite<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_bbp_topic_count":0,"_bbp_reply_count":0,"_bbp_total_topic_count":0,"_bbp_total_reply_count":0,"_bbp_voice_count":0,"_bbp_anonymous_reply_count":0,"_bbp_topic_count_hidden":0,"_bbp_reply_count_hidden":0,"_bbp_forum_subforum_count":0,"footnotes":""},"categories":[16],"tags":[368,772,1145,1416],"class_list":["post-3622","post","type-post","status-publish","format-standard","hentry","category-isolation-ventilation","tag-debits-dair","tag-metres-cubes-dair","tag-renouveler-lair-dans-les-logements","tag-ventiler"],"_links":{"self":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/3622","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/comments?post=3622"}],"version-history":[{"count":0,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/posts\/3622\/revisions"}],"wp:attachment":[{"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/media?parent=3622"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/categories?post=3622"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/plombiers-reunis.com\/v3\/wp-json\/wp\/v2\/tags?post=3622"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}